The trouble with capping stations, such as Caps placed on incorrectly, caps lost, and caps wearing a lot.
1. Cause analysis:
The bending point of the capping plate is incorrect
Solution: Adjust to about 1MM below the center of the cap (no jumping when scraping the cap)
2. Cause analysis:
There is a step at the connection between the capping plate and the screw capping plate
Solution: Adjust the length of the capping plate or grind the length
3. Cause analysis:
The height of the screw capping plate is too low or too high
Solution: Make fine adjustments of about 1MM based on the height of the bottle after capping
4. Cause analysis:
The bottle clamp and the first set of screw-capping wheels are not at the same center
Solution: The bottle stops under the screw capping wheel, and the positive and negative screws are adjusted
5. Cause analysis:
The cap is worn
Solution: The bottle cap is too tight, and the speed and force of screw capping are coordinated (the speed should be as slow as possible)